Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Apply fire extinguishing techniques
Extinguish fires
Extinguisher bottle
Fire bottle
Fire extinguisher
Fire extinguisher bottle
Fire extinguisher pressure
Fire extinguisher system
Fire extinguisher tank
Fire extinguishing
Fire extinguishing system
Fires extinguishing
Firex bottle
Hand extinguisher
Hand fire extinguisher
Hand-held extinguisher
Hand-held fire extinguisher
Hand-portable extinguisher
Hand-portable fire extinguisher
Operate extinguishers
Operate fire extinguishers
Stored pressure extinguisher
Stored pressure fire extinguisher
Use different kinds of fire extinguishers
Use different types of fire extinguishers
Use fire extinguishers
Utilise fire extinguishers
Utilise various types of fire extinguishers

Traduction de «fire extinguisher pressure » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous


use different kinds of fire extinguishers | utilise various types of fire extinguishers | apply fire extinguishing techniques | use different types of fire extinguishers

utiliser différents types d'extincteurs


fire extinguishing | fires extinguishing | extinguish fires | extinguish fires

éteindre un incendie


stored pressure fire extinguisher | stored pressure extinguisher

extincteur à pression permanente | extincteur sous pression permanente | extincteur sous pression


use fire extinguishers | utilise fire extinguishers | operate extinguishers | operate fire extinguishers

utiliser des extincteurs


hand fire extinguisher [ hand extinguisher | hand-held fire extinguisher | hand-portable fire extinguisher | hand-held extinguisher | hand-portable extinguisher ]

extincteur portatif [ extincteur d'incendie portatif | extincteur à main | extincteur transportable à la main | extincteur d'incendie à main ]


fire extinguisher system | fire extinguishing system

système d'extinction incendie


extinguisher bottle | firex bottle | fire extinguisher bottle | fire bottle

bouteille extincteur




fire extinguishing system | fire extinguisher system

installation d'extinction [ FA | fA ]
TRADUCTIONS EN CONTEXTE
The Directive covers a broad range of industrial equipment, such as compressors and heat exchangers, as well as consumer products such as fire extinguishers and pressure cookers.

Cette directive régit une vaste gamme d'équipements industriels, tels que les compresseurs et les échangeurs thermiques, ainsi que des produits de consommation comme les extincteurs et les autocuiseurs.


Specifically, the Commission is requesting: Ireland and Portugal to transpose the Directive on lifts and safety components for lifts (Directive 2014/33/EU) which lays down the requirements that need to be met to place lifts and lift safety components on the EU market while ensuring a high level of safety for lift users and maintenance staff; Portugal to transpose the Directive on pressure equipment (Directive 2014/68/EU), which covers a broad range of industrial equipment, such as compressors and heat exchangers, but also to consumer products such as fire extinguis ...[+++]

La Commission demande plus particulièrement: à l'Irlande et au Portugal de transposer la directive sur les ascenseurs et les composants de sécurité pour ascenseurs (directive 2014/33/UE), qui fixe les conditions qui doivent être remplies pour mettre des ascenseurs et des composants de sécurité pour ascenseurs sur le marché de l'UE tout en assurant un niveau élevé de sécurité pour les utilisateurs d'ascenseurs et le personnel chargé de leur entretien; au Portugal de transposer la directive sur les équipements sous pression (directive 2014/68/ ...[+++]


(i) in the case of a fixed fire-smothering installation or a fire extinguisher in which the extinguishing medium is stored under pressure, a certificate that attests to the examination or test issued by a company engaged in the manufacture or testing of fire-extinguishing equipment, and

(i) dans le cas d’une installation fixe d’étouffement d’incendie ou d’un extincteur qui contient un produit extincteur sous pression, un certificat ou un brevet d’inspection ou d’essai délivré par une société qui fabrique de l’équipement anti-incendie ou qui en fait l’essai, et


(h) in the case of portable and non-portable fluid fire extinguishers, that is to say, those discharging water or foam, the operating mechanism and hose shall be examined and the extinguishers shall be emptied and recharged; and where the inspector has reason to doubt the condition of an extinguisher it shall be tested by hydraulic pressure to 2 068 kPa, and the date this test was carried out shall be marked on the extinguisher;

h) dans le cas des extincteurs à fluide, portatifs ou non, c’est-à-dire ceux qui sont distributeurs d’eau ou de mousse, le mécanisme de commande et les manches seront examinés et les extincteurs seront vidés et rechargés et si l’inspecteur a lieu de douter du bon état d’un extincteur, celui-ci sera éprouvé sous une pression hydraulique de 2 068 kPa et la date de l’épreuve y sera poinçonnée;


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
8 (1) Fire extinguishers in passenger and crew spaces shall be of the fluid type, that is to say those discharging water or foam; extinguishers in which the substance is stored under pressure shall not be provided for use in such spaces, but extinguishers containing only a small capsule of CO may be provided.

8 (1) Les extincteurs d’incendie dans les locaux des passagers et de l’équipage seront à fluide, c’est-à-dire qu’ils ne devront lancer que de l’eau ou de la mousse. Les extincteurs dont le contenu est sous pression ne seront pas utilisés dans ces locaux, mais ceux qui ne contiennent qu’une petite capsule de gaz carbonique pourront l’être.


(4) A fire-extinguishing system utilizing pressure water spray referred to in subsection (1) or (2) shall meet the requirements of National Fire Protection Association 15, Standard for Water Spray Fixed Systems for Fire Protection.

(4) Le système d’extincteurs d’incendie à jet d’eau sous pression visé aux paragraphes (1) ou (2) doit satisfaire aux exigences de la norme 15 de la National Fire Protection Association intitulée Standard for Water Spray Fixed Systems for Fire Protection.


(5) In ships in which the fire extinguishers are of a type that have the shell continuously pressurized with gas and have a trigger and valve device designed to retain the remainder of the charge once part of the contents have been discharged, the requirements for spare charges shall be deemed to be met if the number of extinguishers carried is increased in the ratio of 1.4 to 1 over the basic number required to be carried.

(5) Sur les navires munis d’extincteurs dont l’enveloppe est continuellement soumise à la pression d’un gaz et qui ont un robinet-gâchette pouvant retenir ce qui reste de la charge lorsqu’une partie du contenu a été déchargée, les prescriptions relatives aux charges de rechange sont censées être observées si le nombre des extincteurs à bord est de 1.4 fois le nombre fondamental d’extincteurs à avoir sur le navire.


This European Union law lays down essential safety requirements for pressure equipment and assemblies (such as boilers, pressure cookers, fire extinguishers, heat exchangers and steam generators).

Cette législation de l’Union européenne (UE) établit des exigences essentielles de sécurité relatives aux équipements sous pression et aux ensembles (tels que les chaudières, les autocuiseurs, les extincteurs, les échangeurs thermiques et les dispositifs de production de vapeur).


Transportable pressure equipment shall be understood as including gas cartridges (UN No. 2037) and excluding aerosols (UN No. 1950), open cryogenic receptacles, gas cylinders for breathing apparatus, fire extinguishers (UN No. 1044), transportable pressure equipment exempted according to 1.1.3.2 of the Annexes to Directive 2008/68/EC and transportable pressure equipment exempted from the rules for construction and testing of packaging according to special provisions in 3.3 of the Annexes to Directive 2008/68/EC.

Les équipements sous pression transportables comprennent les cartouches à gaz (n° ONU 2037) mais non les aérosols (n° ONU 1950), les récipients cryogéniques ouverts, les bouteilles de gaz pour les appareils respiratoires, les extincteurs d'incendie (n° ONU 1044), les équipements sous pression transportables exemptés au titre du point 1.1.3.2 des annexes de la directive 2008/68/CE et les équipements sous pression transportables non soumis aux règles relatives à la construction et à l'épreuve des emballages conformément aux dispositions ...[+++]


This Directive applies to simple pressure vessels manufactured in series and does not apply to vessels specifically designed for nuclear use, vessels intended for the propulsion of ships and aircraft and fire extinguishers.

Cette directive s’applique aux récipients à pression simples fabriqués en série et ne s’applique pas aux récipients conçus spécifiquement pour une utilisation dans le domaine nucléaire, ni aux récipients conçus pour la propulsion de navires et d’aéronefs, ni aux extincteurs.


w