Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Abel closed cup apparatus
Abel closed tester
Abel flash point tester
Abel tester
CC flash point test
Closed cup Tag flash point tester
Closed cup flash point
Closed cup flash point test
Closed flash point
Flash closed cup
Flash point cc
Tag closed cup
Tag closed cup flash point tester
Tag closed tester
Tag closed-cup tester
Tagliabue closed cup
Tagliabue closed tester
Tagliabue closed-cup tester

Traduction de «Closed cup Tag flash point tester » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
Tagliabue closed tester [ Tagliabue closed-cup tester | Tag closed-cup tester | Tag closed tester | Tagliabue closed cup | Tag closed cup | closed cup Tag flash point tester ]

appareil à vase clos Tag [ appareil à creuset fermé Tag | appareil Tagliabue à vase clos | appareil Tag à creuset fermé | creuset fermé Tag | vase clos Tag | vase clos Tagliabue ]


Tag closed cup flash point tester

appareil pour la détermination du point d'éclair en vase clos


Abel tester [ Abel flash point tester | Abel closed cup apparatus | Abel closed tester ]

appareil Abel [ appareil à vase clos Abel | appareil à creuset fermé Abel | creuset fermé Abel ]


closed cup flash point | flash point cc | flash closed cup | closed flash point

point d'éclair en vase clos


closed cup flash point test | CC flash point test

test en coupelle fermée


TRADUCTIONS EN CONTEXTE
If relevant for the interpretation of the numerical value, the method of determination shall also be provided (for example, the method for flash point, the open-cup/closed-cup method):

Si cette information est utile à l'interprétation de la valeur numérique, la méthode de détermination doit également être précisée (par exemple la méthode du point d'éclair ou la méthode en vase ouvert/vase clos):


If relevant for the interpretation of the numerical value, the method of determination shall also be provided (for example, the method for flash point, the open-cup/closed-cup method):

Si cette information est utile à l'interprétation de la valeur numérique, la méthode de détermination doit également être précisée (par exemple la méthode du point d'éclair ou la méthode en vase ouvert/vase clos):


(a) a liquid, other than a liquid referred to in paragraph (c) or (d), having a viscosity of less than 5.8 mm /s (45 Saybolt Universal Seconds) at 37.8°C (100°F) is the Standard Test Method for Flash Point by Tag Closed Tester ASTM D56-82, dated August 27, 1982, or the appropriate test in the Standard Test Methods for Flash Point by Setaflash Closed Tester, ASTM D3828-81, dated August 28, 1981;

a) dans le cas d’un liquide dont la viscosité à 37,8 °C (100 °F) est inférieure à 5,8 mm /s (45 secondes universelles Saybolt) et qui n’est pas visé aux alinéas c) ou d), la méthode décrite dans la norme D56-82 de l’ASTM intitulée Standard Test Method for Flash Point by Tag Closed Tester, en date du 27 août 1982, ou la méthode décrite dans la norme D3828-81 de l’ASTM intitulée Standard Test Methods for Flash Point by Setaflash Closed Tester, en date du 28 août 1981;


(d) a paint, enamel, lacquer, varnish or similar liquid that has a flash point between 0°C (32°F) and 110°C (230°F) and a viscosity of less than 15 000 mm /s at 25°C (77°F) determined in accordance with the Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity), ASTM D445-83, dated October 28, 1983, is the appropriate test in the Standard Test Methods for Flash ...[+++]

d) dans le cas de peinture, d’émail, de laque, de vernis ou d’un liquide similaire dont le point d’éclair se situe entre 0° C (32 °F) et 110 °C (230 °F) et dont la viscosité à 25 °C (77 °F) est inférieure à 15 000 mm /s, déterminée selon la méthode D445-83 de l’ASTM intitulée Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity), en date du 28 octobre 1983, la méthode décrite dans la norme D3278-82 de l’ASTM intitulée Standard Test Methods for ...[+++]


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(2) Every Class A ship using fuel having a flash point (Pensky Marten, closed-cup) of less than 52°C, for main or auxiliary purposes shall, in addition to the requirements of subsection (1), be provided in the machinery spaces where such units are used with a permanent piping system for the discharge of smothering gas; the volume of free gas to be provided shall be at least equal to 40 per cent of the total volume of the space (see Schedule III).

(2) Tout navire de la classe A qui, pour ses machines principales ou auxiliaires, emploie du combustible de point éclair (procédé en vase clos de Pensky Marten) inférieur à 52 °C aura dans les locaux de la tranche des machines où ces unités sont utilisées, en sus du matériel exigé au paragraphe (1), un tuyautage permanent de gaz inerte; le volume du gaz libre à fournir sera égal à 40 pour cent au moins du volume total du local (voir l’annexe III).


(b) a liquid, other than a liquid referred to in paragraph (c) or (d), having a viscosity of 5.8 mm /s (45 Saybolt Universal Seconds) or more at 37.8°C (100°F), is the appropriate test in the Standard Test Methods for Flash Point by Pensky-Martens Closed Tester, ASTM D93-80, dated August 29, 1980;

b) dans le cas d’un liquide dont la viscosité à 37,8 °C (100 °F) est égale ou supérieure à 5,8 mm /s (45 secondes universelles Saybolt) et qui n’est pas visé aux alinéas c) ou d), la méthode décrite dans la norme D93-80 de l’ASTM intitulée Standard Test Methods for Flash Point by Pensky-Martens Closed Tester, en date du 29 août 1980;


(c) an aviation turbine fuel is the appropriate test in the Standard Test Methods for Flash Point by Setaflash Closed Tester, ASTM D3828-81, dated August 28, 1981; and

c) dans le cas d’un carburant d’aviation pour moteur à turbine, la méthode décrite dans la norme D3828-81 de l’ASTM intitulée Standard Test Methods for Flash Point by Setaflash Closed Tester, en date du 28 août 1981;