Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Cathode follower
Cathode-coupled circuit
Common anode circuit
Common collector circuit
Common drain circuit
Common-source circuit
Earth return circuit
Earth-fault protection
Earth-return circuit
Earthed collector circuit
Emitter follower
GFCI
GFI
Ground fault circuit interrupter
Ground fault interrupter
Ground return circuit
Ground return path
Ground-fault circuit interrupter
Ground-fault circuit protection
Ground-fault interrupter
Ground-fault protection
Ground-return circuit
Grounded anode amplifier
Grounded anode circuit
Grounded collector circuit
Grounded drain circuit
Grounded source circuit
RCCB
RCD
Residual-current circuit breaker
Residual-current device
Source follower

Traduction de «Grounded source circuit » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
common-source circuit [ grounded source circuit ]

circuit à source commune


common drain circuit | grounded drain circuit | source follower

source suiveuse


cathode follower | cathode-coupled circuit | common anode circuit | grounded anode amplifier | grounded anode circuit

amplificateur à anode mise à la masse | amplificateur cathodyne à triode | montage à cathode asservie


ground return circuit [ ground return path | earth-return circuit ]

circuit de retour par la terre [ trajet de retour par la terre ]


common collector circuit | earthed collector circuit | emitter follower | grounded collector circuit

émetteur suiveur


ground-fault circuit interrupter [ GFCI | ground-fault interrupter ]

disjoncteur de fuite de terre [ différentiel ]


residual-current circuit breaker | RCCB | residual-current device | RCD | ground fault circuit interrupter | GFCI | ground fault interrupter | GFI

disjoncteur différentiel de fuite à la terre | DDFT | disjoncteur-détecteur de fuite à la terre | DDFT | disjoncteur de fuite à la terre | disjoncteur différentiel | interrupteur différentiel


ground-return circuit | earth return circuit | earth-return circuit

circuit à retour par la terre | circuit de retour par la terre | circuit à retour par la masse


ground-fault circuit protection | ground-fault protection | earth-fault protection

protection contre les défauts à la terre | protection de terre
TRADUCTIONS EN CONTEXTE
(5) Every conducting part of a safety ground on isolated electrical equipment must have sufficient current carrying capacity to conduct the maximum current that is likely to be carried on any part of the equipment for the time that is necessary to permit operation of any device that is installed on the electrical equipment so that, in the event of a short circuit or other electrical current overload, the electrical equipment is automatically disconnected from its source of electr ...[+++]

(5) Toute partie conductrice de la prise de terre d’un outillage électrique isolé a une capacité de transport suffisante pour laisser passer, pendant la période nécessaire au fonctionnement de tout dispositif installé sur l’outillage électrique, l’intensité de courant maximale qu’une partie quelconque de l’outillage est susceptible de porter de sorte qu’en cas de court-circuit ou de toute autre surcharge de courant électrique, l’outillage électrique soit automatiquement coupé à la source.


8.21 Every conducting part of a safety ground on isolated electrical equipment shall have sufficient current carrying capacity to conduct the maximum current that is likely to be carried on any part of the equipment for such time as is necessary to permit operation of any device that is installed on the electrical equipment so that, in the event of a short circuit or other electrical current overload, the electrical equipment is automatically disconnected from its source of electr ...[+++]

8.21 Toute partie conductrice de la prise de terre d’un outillage électrique isolé doit avoir une capacité suffisante pour laisser passer, pendant la période nécessaire à l’installation de tout dispositif sur l’outillage électrique, l’intensité de courant maximale qu’une partie quelconque de l’outillage est susceptible de porter de sorte qu’en cas de court-circuit ou de toute autre surcharge de courant électrique, l’outillage électrique soit automatiquement coupé à la source.