Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Back pressure regulator
Back pressure valve
Back-pressure valve
Check valve
Constant pressure valve
Evaporator pressure regulator
Float valve
Hydraulic back pressure valve
Non-return valve
Two-temperature valve

Traduction de «Hydraulic back pressure valve » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
hydraulic back pressure valve

intercepteur hydraulique | soupape hydraulique




back pressure regulator | back pressure valve | constant pressure valve | evaporator pressure regulator | two-temperature valve

régulateur de pression d'évaporation | robinet à pression minimale constante


evaporator pressure regulator [ back pressure regulator | constant pressure valve | back pressure valve | two-temperature valve ]

régulateur de pression d'évaporation [ robinet à pression constante | robinet à pression minimale constante ]


back-pressure valve | check valve

clapet de non-retour | clapet de retenue | soupape de retenue


check valve | non-return valve | back pressure valve | float valve

clapet de non-retour | clapet de non retour | clapet de retenue | clapet antiretour | soupape de retenue | soupape antiretour


back-pressure valve

vanne de régulation de contre-pression






TRADUCTIONS EN CONTEXTE
245. Unless otherwise authorized by specifications established by the Minister, all meters except slow-flow meters and slow-flow dispensers shall have an automatic air-vapour eliminator and a meter for liquefied gases shall also have a combination differential-pressure and back-pressure valve.

245. Sauf autorisation donnée dans des prescriptions qu’établit le ministre, un compteur, excepté les distributeurs et compteurs à débit lent, doit être muni d’un éliminateur air-vapeur automatique, et un compteur à gaz liquéfié doit comporter en plus un clapet à contre-pression et pression différentielle.


245. Unless otherwise authorized by specifications established by the Minister, all meters except slow-flow meters and slow-flow dispensers shall have an automatic air-vapour eliminator and a meter for liquefied gases shall also have a combination differential-pressure and back-pressure valve.

245. Sauf autorisation donnée dans des prescriptions qu’établit le ministre, un compteur, excepté les distributeurs et compteurs à débit lent, doit être muni d’un éliminateur air-vapeur automatique, et un compteur à gaz liquéfié doit comporter en plus un clapet à contre-pression et pression différentielle.


1.3.3. The valve shall open when the exhaust-gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 0,35 and 0,40 kPa.

1.3.3. La soupape s'ouvre lorsque la contre-pression des gaz d'échappement, mesurée à 100 mm au moins en aval de la bride d'entrée, atteint une valeur comprise entre 0,35 et 0,40 kPa.


The valve shall open when the exhaust gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 35 and 40 kPa.

La soupape s'ouvre lorsque la contre-pression des gaz d'échappement, mesurée à 100 mm au moins en aval de la bride d'entrée, atteint une valeur comprise entre 35 et 40 kPa.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
The valve shall open when the exhaust-gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 0,35 and 0,40 kP a. It shall close when this pressure does not differ by more than 10 per cent from its stabilized value with the valve open.

La soupape doit s’ouvrir lorsque la contre-pression des gaz d’échappement, mesurée à 100 mm au moins en aval de la bride d’entrée, atteint une valeur comprise entre 0,35 et 0,40 kPa. Elle doit se refermer lorsque cette pression ne s’écarte pas de plus de 10 % de sa valeur stabilisée lorsqu’elle est ouverte.


The valve shall open when the exhaust gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 35 and 40 kP a. It shall close when this pressure does not differ by more than 10 % from its stabilized value with the valve opened.

La soupape doit s’ouvrir lorsque la contre-pression des gaz d’échappement, mesurée à 100 mm au moins en aval de la bride d’entrée, atteint une valeur comprise entre 35 et 40 kPa. Elle doit se fermer quand cette pression ne s’écarte pas de plus de 10 % de sa valeur stabilisée quand la soupape est ouverte.


2.3. All approved bottom-loading vehicles will carry an identification plate which specified the maximum permitted number of loading arms which may be operated simultaneously whilst ensuring that no vapours are released via the compartment P and V valves, when the maximum plant back pressure is 55 millibar as specified in 2.2.

2.3. Tous les véhicules homologués à chargement en source seront munis d'une plaque d'identification spécifiant le nombre maximal autorisé de bras de chargement qui peuvent être actionnés simultanément tout en évitant la fuite de vapeurs via les soupapes P et V des compartiments lorsque la contrepression maximale du système est de 55 millibars comme spécifié au point 2.2.


The valve must open when the exhaust-gas back pressure, measured at least 100 mm downstream of the intake flange, reaches a value of between 0 735 and 0 740 bar.

L'ouverture de la soupape doit se produire lorsque la contrepression des gaz d'échappement, mesurée à 100 mm au moins en aval de la bride d'entrée, atteint une valeur comprise entre 0,35 et 0,40 bar.


They are also fail-safe valves such that if we happen to lose hydraulic pressure to those valves, the loss is spring-loaded and the valve will close immediately.

Il y a aussi des valves à sécurité intégrée, de sorte que si nous perdons la pression hydraulique qu'il y a dans ces valves, la perte active un ressort et la valve se ferme immédiatement.


Third, a fail-safe subsurface safety valve is also installed in the production tubing string — fail-safe meaning it will stay open only when positive hydraulic pressure is applied to it from the surface through a line from the drilling rig or in production operation from the production facility itself.

Troisièmement, une vanne de sécurité subsurface à sécurité positive est également installée dans le tube de production — sécurité positive veut dire que le tube ne demeure ouvert que lorsqu'on lui applique une pression hydraulique positive à partir de la surface à l'aide d'un tuyau se trouvant sur l'appareil de forage, ou en mode production, sur l'installation de production.