Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
CC flash point test
Closed container flash point determination
Closed cup flash point
Closed cup flash point test
Closed flash point
Closed-cup flash point
Flash closed cup
Flash point cc
Flash point determination

Traduction de «closed container flash point determination » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
closed container flash point determination

termination en vase clos du point d'éclair


closed cup flash point | flash point cc | flash closed cup | closed flash point

point d'éclair en vase clos


closed cup flash point [ closed-cup flash point ]

point d'éclair en vase clos [ point d'éclair en creuset fermé | point d'éclair en cuvette fermée ]


closed cup flash point test | CC flash point test

test en coupelle fere


flash point determination

détermination du point d'éclair


TRADUCTIONS EN CONTEXTE
If relevant for the interpretation of the numerical value, the method of determination shall also be provided (for example, the method for flash point, the open-cup/closed-cup method):

Si cette information est utile à l'interprétation de la valeur numérique, la méthode de détermination doit également être précisée (par exemple la méthode du point d'éclair ou la méthode en vase ouvert/vase clos):


(d) a paint, enamel, lacquer, varnish or similar liquid that has a flash point between 0°C (32°F) and 110°C (230°F) and a viscosity of less than 15 000 mm /s at 25°C (77°F) determined in accordance with the Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity), ASTM D445-83, dated October 28, 1983, is the appropriate test in the Standard Test Methods for Flash Point of Liquids by Setaflash ...[+++]

d) dans le cas de peinture, d’émail, de laque, de vernis ou d’un liquide similaire dont le point d’éclair se situe entre 0° C (32 °F) et 110 °C (230 °F) et dont la viscosité à 25 °C (77 °F) est inférieure à 15 000 mm /s, déterminée selon la méthode D445-83 de l’ASTM intitulée Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity), en date du 28 octobre 1983, la méthode décrite dans la norme D3278-82 de l’ASTM intitulée Standard Test Methods for Flash Point of Liquids by Setaflash ...[+++]


(a) a liquid, other than a liquid referred to in paragraph (c) or (d), having a viscosity of less than 5.8 mm /s (45 Saybolt Universal Seconds) at 37.8°C (100°F) is the Standard Test Method for Flash Point by Tag Closed Tester ASTM D56-82, dated August 27, 1982, or the appropriate test in the Standard Test Methods for Flash Point by Setaflash Closed Tester, ASTM D3828-81, dated August 28, 1981;

a) dans le cas d’un liquide dont la viscosité à 37,8 °C (100 °F) est inférieure à 5,8 mm /s (45 secondes universelles Saybolt) et qui n’est pas visé aux alinéas c) ou d), la méthode décrite dans la norme D56-82 de l’ASTM intitulée Standard Test Method for Flash Point by Tag Closed Tester, en date du 27 août 1982, ou la méthode décrite dans la norme D3828-81 de l’ASTM intitulée Standard Test Methods for Flash Point by Setaflash Closed Tester, en date du 28 août 1981;


(b) a liquid, other than a liquid referred to in paragraph (c) or (d), having a viscosity of 5.8 mm /s (45 Saybolt Universal Seconds) or more at 37.8°C (100°F), is the appropriate test in the Standard Test Methods for Flash Point by Pensky-Martens Closed Tester, ASTM D93-80, dated August 29, 1980;

b) dans le cas d’un liquide dont la viscosité à 37,8 °C (100 °F) est égale ou supérieure à 5,8 mm /s (45 secondes universelles Saybolt) et qui n’est pas visé aux alinéas c) ou d), la méthode décrite dans la norme D93-80 de l’ASTM intitulée Standard Test Methods for Flash Point by Pensky-Martens Closed Tester, en date du 29 août 1980;


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(2) Every Class A ship using fuel having a flash point (Pensky Marten, closed-cup) of less than 52°C, for main or auxiliary purposes shall, in addition to the requirements of subsection (1), be provided in the machinery spaces where such units are used with a permanent piping system for the discharge of smothering gas; the volume of free gas to be provided shall be at least equal to 40 per cent of the total volume of the space (see Schedule III).

(2) Tout navire de la classe A qui, pour ses machines principales ou auxiliaires, emploie du combustible de point éclair (procédé en vase clos de Pensky Marten) inférieur à 52 °C aura dans les locaux de la tranche des machines où ces unités sont utilisées, en sus du matériel exigé au paragraphe (1), un tuyautage permanent de gaz inerte; le volume du gaz libre à fournir sera égal à 40 pour cent au moins du volume total du local (voir l’annexe III).


In terms of the effect of closed containment aquaculture on rural coastal communities, which currently depend on net pen aquaculture, John Holder, who some of you have heard of, made the point to us very clearly that closed containment aquaculture facilities can be moved anywhere close to markets, whereas coastal net pen aquaculture has to be close to, obviously, coastal rural communities.

En ce qui concerne les effets de l'aquaculture en parcs clos sur les collectivités côtières en milieu rural, qui dépendent actuellement de l'aquaculture en parcs en filet, John Holder, dont vous avez entendu parler, nous a dit très clairement que les installations d'aquaculture en parcs clos peuvent être transportées partout, près des marchés, alors que l'aquaculture côtière en parcs en filet doit évidemment demeurée dans les collectivités côtières en ...[+++]


1.7. Deterioration factors are determined using either the procedures set out in points 1.2 and 1.3 or using the assigned values in the table contained in point 1.4.

1.7. Les facteurs de détérioration sont déterminés sur la base des procédures définies aux points 1.2 et 1.3 ou des valeurs attribuées prévues au tableau du point 1.4.


a. Flash point is determined using the Cleveland Open Cup Method described in ASTM D-92 or national equivalents;

a. le point d'éclair est déterminé au moyen de la méthode Cleveland à vase ouvert, décrite dans la norme D-92 de l'ASTM, ou des équivalents nationaux;


(f) by way of derogation from the first paragraph of point K.6 of Annex VI, when kept at a temperature of 20 °C in closed containers, quality aromatic sparkling wines must have an excess pressure of not less than 3 bar;

f) par dérogation au point K 6, premier alinéa, de l'annexe VI, les vins mousseux de qualité du type aromatique accusent, lorsqu'ils sont conservés à la température de 20 °C dans des récipients fermés, une surpression non inférieure à 3 bars;


The method of determining the flash point is defined in Annex V to Council Directive 67/548/EEC (1) of 27 June 1967 concerning the approximation of the laws, regulations and administrative provisions of the Member States relating to the classification, packaging and labelling, of dangerous substances, as last amended by Directive 73/146/EEC (2);

La méthode de détermination du point d'éclair est définie à l'annexe V de la directive 67/548/CEE du Conseil, du 27 juin 1967, concernant le rapprochement des dispositions législatives, réglementaires et administratives des États membres relatives à la classification, l'emballage et l'étiquetage des substances dangereuses (1), modifiée en dernier lieu par la directive 73/146/CEE (2).