Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Acoustic insulant
Acoustic insulating material
Acoustical insulation material
Archival value
Building insulation
Continuing value
Deprival value
Enduring value
Entity value
Entity-specific value
Evidential-archival value
Fire insulation value
Franklin insulation value
Heat insulation
Heat insulator
Historical value
Indefinite value
Insulant
Insulating glazed unit
Insulating glazing
Insulating glazing unit
Insulating material
Insulating value
Insulating-glass unit
Insulation
Insulation material
Insulation value
Lasting value
Long-term value
Opportunity value
Permanent value
Research value
Retention value
Secondary value
Sound insulation
Sound-insulating material
Soundproof material
Thermal insulation
Thermal insulator
Value to the business
Value to the firm

Traduction de «insulation value » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous


fire insulation value

degré d'isolation contre l'incendie






building insulation [ Insulation(ECLAS) ]

isolation de bâtiment


insulating glazed unit | insulating glazing | insulating glazing unit | insulating-glass unit

vitrage isolant


insulant [ insulation | insulating material | insulation material | acoustic insulant | acoustic insulating material | acoustical insulation material | sound-insulating material | sound insulation | soundproof material ]

matériau acoustique isolant [ matériau isolant | matériau d'isolation | matériau d'isolation acoustique | matériau d'isolation phonique | isolant acoustique | isolant phonique | matériau phono-isolant | isolant | matériau insonorisant | matériau insonore ]


archival value [ historical value | continuing value | enduring value | secondary value | long-term value | permanent value | indefinite value | lasting value | research value | evidential-archival value ]

valeur archivistique [ valeur historique | valeur durable | valeur permanente | valeur secondaire ]


value to the firm | deprival value | entity value | entity-specific value | opportunity value | retention value | value to the business

valeur pour l'entreprise | valeur d'utilité pour l'entreprise | valeur d'utilisation pour l'entreprise


thermal insulation | heat insulation | thermal insulator | heat insulator

isolant thermique | calorifuge
TRADUCTIONS EN CONTEXTE
(3) Where a primary or secondary distribution system for power, heating or lighting, with no connection to earth, is used on an offshore installation, a device capable of continuously monitoring the insulation level to earth and of giving an audible or visual indication of abnormally low insulation values shall be provided.

(3) Lorsqu’un système de distribution primaire ou secondaire d’énergie, de chauffage ou d’éclairage est utilisé, sans mise à la terre, dans l’installation au large des côtes, celle-ci doit être dotée d’un dispositif de surveillance continuel du niveau d’isolation à la terre qui est capable de donner une indication sonore ou visuelle en cas de niveau d’isolation anormalement bas.


41 (1) Every “A” Class division shall be constructed of steel or similar material, in either case stiffened so as to be capable of preventing the passage of smoke and flame throughout a standard fire test of 60 minutes duration; the division shall have an adequate insulating value having regard to the nature of the spaces adjacent thereto, and if the division is between spaces either of which contains adjacent combustible material, it shall be so insulated that, if either face of the division is exposed to a standard fire test of 60 minutes duration, the average temperature on the unexposed face ...[+++]

41 (1) Toute cloison type A sera construite en acier ou autre matériau semblable, armaturée dans un cas comme dans l’autre de façon à pouvoir empêcher le passage de la fumée et des flammes pendant toute la durée d’un essai au feu standard de 60 minutes. Elle présentera un degré d’isolement suffisant, compte tenu de la nature des locaux contigus, et, si elle sépare des locaux dont l’un ou l’autre comporte des matériaux combustibles en contact avec elle, elle sera isolée de telle sorte que, si l’une ou l’autre de ses surfaces est soumise pendant 60 minutes à un essai au feu standard, la température moyenne de la surface non exposée n’augme ...[+++]


(3) Where a primary or secondary distribution system for power, heating or lighting, with no connection to earth, is used on an installation, a device capable of continuously monitoring the insulation level to earth and of giving an audible or visual indication of abnormally low insulation values shall be provided.

(3) Lorsqu’un système de distribution primaire ou secondaire d’énergie, de chauffage ou d’éclairage est utilisé, sans mise à la terre, dans l’installation, celle-ci doit être dotée d’un dispositif de surveillance continuel du niveau d’isolation à la terre qui est capable de donner une indication sonore ou visuelle en cas de niveau d’isolation anormalement bas.


62. The boundary bulkheads and decks separating accommodation spaces from machinery, cargo and service spaces shall be constructed as “A” Class divisions, and these bulkheads and decks shall have an insulation value to the satisfaction of the Board having regard to the nature of the adjacent spaces.

62. Les cloisons et les ponts qui séparent les locaux habités des locaux de machines, des locaux à marchandises et des locaux de service seront des cloisons type A, et ces cloisons et ponts devront avoir un degré d’isolation jugé satisfaisant par le Bureau, eu égard à la nature des locaux adjacents.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
8547 | Insulating fittings for electrical machines, appliances or equipment, being fittings wholly of insulating materials apart from any minor components of metal (for example, threaded sockets) incorporated during moulding solely for purposes of assembly, other than insulators of heading 8546; electrical conduit tubing and joints therefor, of base metal lined with insulating material | Manufacture in which the value of all the materials used does not exceed 45 % of the ex-works price of the product | |

8547 | Pièces isolantes, entièrement en matières isolantes ou comportant de simples pièces métalliques d'assemblage (douilles à pas de vis, par exemple) noyées dans la masse, pour machines, appareils ou installations électriques, autres que les isolateurs du no8546; tubes isolateurs et leurs pièces de raccordement, en métaux communs, isolés intérieurement | Fabrication dans laquelle la valeur de toutes les matières utilisées ne doit pas excéder 45 % du prix départ usine du produit | |


they demonstrate an insulation value such that the average temperature on the side facing away from the fire rises to not more than 140 °C above the initial temperature and at no point, including the gaps at the joints, does a temperature increase of more than 225 °C above the initial temperature occur within the following specified periods:

ils possèdent un degré d'isolation tel que la température moyenne de la face non exposée au feu ne s'élève pas de plus de 140 °C par rapport à la température initiale, et que la température en un point quelconque de cette surface, y compris les discontinuités aux joints, ne s'élève pas de plus de 225 °C par rapport à la température initiale dans les délais précisés ci-après:


8547 | Insulating fittings for electrical machines, appliances or equipment, being fittings wholly of insulating materials apart from any minor components of metal (for example, threaded sockets) incorporated during moulding solely for purposes of assembly, other than insulators of heading 8546; electrical conduit tubing and joints therefor, of base metal lined with insulating material | Manufacture in which the value of all the materials used does not exceed 40 % of the ex-works price of the product | |

8547 | Pièces isolantes, entièrement en matières isolantes ou comportant de simples pièces métalliques d’assemblage (douilles à pas de vis, par exemple) noyées dans la masse, pour machines, appareils ou installations électriques, autres que les isolateurs du no8546; tubes isolateurs et leurs pièces de raccordement, en métaux communs; isolés intérieurement | Fabrication dans laquelle la valeur de toutes les matières utilisées ne doit pas excéder 40 % du prix départ usine du produit | |


- special insulation against the noise in question, meaning special insulation of a building against one or more types of environmental noise, combined with such ventilation or air conditioning facilities that high values of insulation against environmental noise can be maintained,

- spécialement isolées contre le bruit en question, c'est-à-dire équipées d'un système d'isolation spécial contre un ou plusieurs types de bruit dans l'environnement, combiné avec des installations de ventilation ou de conditionnement d'air telles qu'un niveau élevé d'isolation contre le bruit dans l'environnement peut être maintenu,


Mr. Mac Harb (Parliamentary Secretary to Minister for International Trade): Mr. Speaker, it is my pleasure to rise in the House and address the issue of urea formaldehyde foam insulation and in particular its effect on market value of homes insulated with UFFI. As my hon. colleague pointed out, during the 1970s many homes were insulated with UFFI. Let me assure everyone that no Canadian whose home has been insulated with UFFI has been denied mortgage insurance from Canada Mortgage and Housing Corporation.

M. Mac Harb (secrétaire parlementaire du ministre du Commerce international): Monsieur le Président, je suis heureux de prendre la parole à la Chambre pour aborder la question de la mousse isolante d'urée-formaldéhyde et particulièrement celle de la valeur marchande des maisons isolées à la MIUF. Comme mon collègue l'a signalé, durant les années 1970, on se servait beaucoup de la MIUF pour isoler les maisons.


The radial thickness of the insulation must be at least 25 mm. The thermal conductivity of the insulating material must have a value no greater than 0,1 W/mk measured at 673 K (300 oC).

L'épaisseur radiale de l'isolation doit être d'au moins 25 mm. La conductivité thermique du matériau isolant ne peut présenter une valeur supérieure à 0,1 W/mk mesurée à 673 K (300 oC).


w