Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Circulating hot water system
Heat pump waste heat recovery system
Heat recovery
Heat recuperation
Hot water circulating system
Hot water heating
Hot water heating system
Hot-water heating
Hot-water heating system
Hydronic central heating system
Hydronic heat
Hydronic heating
Low grade heat
Low temperature heat
Low temperature waste heat recovery
Low-grade heat
Low-temperature heat
Low-temperature water heating system
Low-temperature-water heating system
Waste heat boiler
Waste heat recovery
Waste heat-recovery boiler
Waste-heat recovery

Traduction de «low temperature waste heat recovery » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
low temperature waste heat recovery

récupération de chaleur à basse température


heat recovery [ waste-heat recovery | waste heat recovery ]

récupération de chaleur


heat recovery | heat recuperation | waste heat recovery | waste-heat recovery

récupération de chaleur | récupération de la chaleur | récupération thermique


hot water heating system [ hot-water heating system | hot water circulating system | circulating hot water system | low-temperature water heating system | low-temperature-water heating system | hot-water heating | hot water heating | hydronic heating | hydronic central heating system | hydronic heat ]

système de chauffage à eau chaude [ installation de chauffage à eau chaude | installation de chauffage central à eau chaude | installation à eau chaude | système à eau chaude | installation à eau chaude basse pression ]


waste heat-recovery boiler | waste heat boiler

chaudière de récupération de chaleur


heat pump waste heat recovery system

système de récupération de la chaleur perdue par pompe à chaleur




low-grade heat | low-temperature heat

chaleur basse température


low grade heat | low temperature heat

chaleur à basse température | chaleur de basse énergie
TRADUCTIONS EN CONTEXTE
The development of the 2030 climate policy will, without prejudice to the outcome of the public consultation launched by the Green Paper “A 2030 framework for climate and energy policies” endeavour to take into account, inter alia, the international competitiveness of the European industry as well as the specific features of certain industries and progress in the global climate change negotiations as well as an assessment of all relevant CO2 emissions in the EU, – ensure that the assessment of the risk of carbon leakage to be done in the context of the new carbon leakage list is performed in an open and transparent manner in accordance with the requirements of the ETS Directive taking into account the specific features of certain industries ...[+++]

Sans préjudice du résultat de la consultation publique lancée par le livre vert «Un cadre pour les politiques en matière de climat et d’énergie à l’horizon 2030», il sera notamment tenu compte dans l’élaboration de la politique en matière de climat pour 2030, de la compétitivité internationale de l’industrie européenne ainsi que des caractéristiques spécifiques de certaines industries et des progrès réalisés dans les négociations à l’échelle mondiale sur le changement climatique, de même que d’une évaluation de toutes les émissions de CO2 concernées dans l’Union; – faire en sorte que l’évaluation du risque de fuite de carbone à effectue ...[+++]


low-temperature heat pump’ means a heat pump space heater that is specifically designed for low-temperature application, and that cannot deliver heating water with an outlet temperature of 52 °C at an inlet dry (wet) bulb temperature of – 7 °C (– 8 °C) in the reference design conditions for average climate.

«pompe à chaleur basse température», un dispositif de chauffage des locaux par pompe à chaleur spécifiquement conçu pour l’application à basse température, et qui ne peut pas, dans les conditions de conception de référence correspondant aux conditions climatiques moyennes, fournir de l’eau de chauffage à une température de sortie de 52 °C pour une température d’entrée de bulbe sec (humide) de – 7 °C (– 8 °C).


low-temperature application’ means an application where the heat pump space heater delivers its declared capacity for heating at an indoor heat exchanger outlet temperature of 35 °C.

«application à basse température», une application dans laquelle un dispositif de chauffage des locaux par pompe à chaleur fournit sa puissance calorifique déclarée pour une température de sortie de l’échangeur thermique intérieur de 35 °C.


low-temperature heat pump’ means a heat pump space heater that is specifically designed for low-temperature application, and that cannot deliver heating water with an outlet temperature of 52 °C at an inlet dry (wet) bulb temperature of – 7 °C (– 8 °C) in the reference design conditions for average climate;

«pompe à chaleur basse température», un dispositif de chauffage des locaux par pompe à chaleur spécifiquement conçu pour l’application à basse température, et qui ne peut pas, dans les conditions de conception de référence correspondant aux conditions climatiques moyennes, fournir de l’eau de chauffage à une température de sortie de 52 °C pour une température d’entrée de bulbe sec (humide) de – 7 °C (– 8 °C);


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
an industrial installation with a total thermal input exceeding 20 MW generating waste heat at a useful temperature level is planned or substantially refurbished, in order to assess the cost and benefits of utilising the waste heat to satisfy economically justified demand, including through cogeneration, and of the connection of that installation to a district heating and cooling network.

une installation industrielle d'une puissance thermique totale supérieure à 20 MW génératrice de chaleur fatale à un niveau de température utile est planifiée ou fait l'objet d'une rénovation substantielle, afin d'évaluer les coûts et les avantages d'une valorisation de la chaleur fatale en vue de satisfaire à une demande justifiée du point de vue économique, y compris par la cogénération, et du raccordement de cette installation à un réseau de chaleur et de froid.


The applicability of fuel preheating depends on the efficiency of the stoves as this determines the waste gas temperature (e.g. at waste gas temperatures below 250 °C, heat recovery may not be a technically or economically viable option).

L'applicabilité du préchauffage du combustible dépend de l'efficacité des cowpers, car c'est ce qui détermine la température des effluents gazeux (par exemple, si la température des effluents gazeux est inférieure à 250 °C, la récupération de la chaleur risque de ne pas être une option viable sur le plan technique ou économique).


a basic understanding of the physical and operation principles of a heat pump, including characteristics of the heat pump circle: context between low temperatures of the heat sink, high temperatures of the heat source, and the efficiency of the system, determination of the coefficient of performance (COP) and seasonal performance factor (SPF).

une compréhension élémentaire des principes physiques et des règles de fonctionnement d’une pompe à chaleur, y compris les caractéristiques du circuit de la pompe: relation entre les basses températures du dissipateur, les hautes températures de la source de chaleur et l’efficacité du système, détermination du coefficient de performance (COP) et du coefficient de performance saisonnier (CPS).


(i)a basic understanding of the physical and operation principles of a heat pump, including characteristics of the heat pump circle: context between low temperatures of the heat sink, high temperatures of the heat source, and the efficiency of the system, determination of the coefficient of performance (COP) and seasonal performance factor (SPF).

i)une compréhension élémentaire des principes physiques et des règles de fonctionnement d’une pompe à chaleur, y compris les caractéristiques du circuit de la pompe: relation entre les basses températures du dissipateur, les hautes températures de la source de chaleur et l’efficacité du système, détermination du coefficient de performance (COP) et du coefficient de performance saisonnier (CPS).


a basic understanding of the physical and operation principles of a heat pump, including characteristics of the heat pump circle: context between low temperatures of the heat sink, high temperatures of the heat source, and the efficiency of the system, determination of the coefficient of performance (COP) and seasonal performance factor (SPF);

une compréhension élémentaire des principes physiques et des règles de fonctionnement d’une pompe à chaleur, y compris les caractéristiques du circuit de la pompe: relation entre les basses températures du dissipateur, les hautes températures de la source de chaleur et l’efficacité du système, détermination du coefficient de performance (COP) et du coefficient de performance saisonnier (CPS);


Utilising waste heat for domestic heating, cooling or other low-temperature heating purposes allows even higher overall efficiencies.

L'utilisation de la chaleur de déperdition pour le chauffage ou le refroidissement domestique ou pour d'autres utilisations de chauffage à basse température permet d'atteindre un rendement énergétique global encore supérieur.




datacenter (1): www.wordscope.fr (v4.0.br)

'low temperature waste heat recovery' ->

Date index: 2021-12-27
w