Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Heating may cause a fire or explosion.
Self-heating may catch fire.
Self-heating in large quantities; may catch fire.

Traduction de «self-heating may catch fire » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
Self-heating: may catch fire.

Matière auto-échauffante; peut s’enflammer.


Self-heating in large quantities; may catch fire.

Matière auto-échauffante en grandes quantités; peut s’enflammer.


Heating may cause a fire or explosion.

Peut s’enflammer ou exploser sous l’effet de la chaleur.
TRADUCTIONS EN CONTEXTE
In Regulation 1272/2008 self-reactive substances and mixtures (2.8) types CD, EF may cause fire when heated, oxidising liquids (2.13) category 3 may intensify fire, and oxidising solids (2.14) category 3 may intensify fire, therefore they should be included in the list of hazardous chemical agents.

Dans le règlement (CE) n° 1272/2008, les substances et mélanges autoréactifs (2.8) de types C, D, E et F peuvent s'enflammer en cas d'échauffement, les liquides comburants (2.13) de la catégorie 3 peuvent aggraver l'incendie, et les matières solides comburantes (2.14) de la catégorie 3 peuvent aggraver l'incendie; c'est pourquoi ces substances doivent être intégrées dans la liste des agents chimiques dangereux.


solid substances and preparations which may readily catch fire after brief contact with a source of ignition and which continue to burn or to be consumed after removal of the source of ignition; or

à l'état solide, qui peuvent s'enflammer facilement par une brève action d'une source d'inflammation et qui continuent à brûler ou à se consumer après le retrait de la source d'inflammation; ou


substances and preparations which may become hot and finally catch fire in contact with air at ambient temperature without any application of energy; or

pouvant s'échauffer au point de s'enflammer à l'air à température ambiante sans apport d'énergie; ou


18. All storage facilities, except those that are self-ventilating under fire conditions, shall be ventilated with permanently open ventilators to assist in the dissipation of the heat and gases produced by the decomposition of ammonium nitrate in a fire.

18. Toutes les installations d’emmagasinage, à l’exception de celles qui sont à ventilation automatique en cas d’incendie, auront des ventilateurs ouverts en permanence de façon à aider à la dissipation de la chaleur et des gaz que produit la décomposition du nitrate d’ammonium dans un incendie.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(2) Every stairway that is located in an accommodation space, service space or control station and that penetrates more than a single deck shall be enclosed in a stairtower of at least ‘A-0’ Class fire rating construction and have self-closing fire doors fitted at every level but the stairtower may be of ‘B-0’ Class fire rating construction if

(2) Les escaliers situés dans un local d’habitation, un local de service ou un poste de sécurité et qui traversent plus d’un pont doivent être situés dans une cage d’escalier ayant au moins un indice de résistance au feu de type A-0 et être dotés à tous les niveaux de portes coupe-feu à fermeture automatique; la cage d’escalier peut toutefois avoir un indice de résistance au feu de type B-0,


(2) The alternative means of extinguishing fire may be met by providing an independent, self-contained, compressionignition, engine-driven pumping unit in accordance with the requirements of section 2 of Schedule II; but, where it is shown to the satisfaction of the Board that such an arrangement is unreasonable or impracticable, the fitting of smothering gas as alternative means of extinguishing the fire may be allowed; the smothering gas to be provided as an alternative means shall be in accordance with section 7 of Schedule III.

(2) Les autres moyens d’extinction pourront consister en un groupe de pompage indépendant et autonome, actionné par un moteur à allumage par compression, conformément aux prescriptions de l’article 2 de l’annexe II; toutefois, le Bureau pourra, s’il est démontré à sa satisfaction qu’un tel arrangement serait déraisonnable ou pratiquement impossible, admettre une quantité de gaz inerte comme autre moyen d’extinction, laquelle devra satisfaire aux prescriptions de l’article 7 de l’annexe III.


(2) Every stairway that is located in an accommodation space, service space or control station and that penetrates more than a single deck shall be enclosed in a stairtower of at least ‘A-0’ Class fire rating contruction and have self-closing fire doors fitted at every level but the stairtower may be of ‘B-0’ Class fire rating construction if

(2) Les escaliers situés dans un local d’habitation, un local de service ou un poste de sécurité et qui traversent plus d’un pont doivent être situés dans une cage d’escalier ayant au moins un indice de résistance au feu de type A-0 et être dotés à tous les niveaux de portes coupe-feu à fermeture automatique; la cage d’escalier peut toutefois avoir un indice de résistance au feu de type B-0,


Question No. 382 Ms. Elizabeth May: With regard to the current and projected impacts of anthropogenic climatic change and disruption including, but not limited to, increasing water scarcity, forest fire frequency and severity, degradation of permafrost-dependent infrastructure, frequency of extreme weather events including floods and heat waves, sea level rise, and the spread of vector-borne diseases such as Lyme Disease, for each department, what ar ...[+++]

Question n 382 Mme Elizabeth May: En ce qui concerne les incidences actuelles et prévues des bouleversements et des changements climatiques anthropiques, notamment la pénurie grandissante d’eau, l’augmentation de la fréquence et de la gravité des feux de forêt, la dégradation des infrastructures liée à la fonte du pergélisol, la fréquence accrue de phénomènes météorologiques extrêmes tels que les inondations ou les vagues de chaleur, l’élévation du niveau de la mer et la propagation de maladies à transmission vectorielle comme la maladie de Lyme, pour chaque ministère, quels sont les coûts détaillés actuels et prévus se rattachant à l’ad ...[+++]


substances and preparations which may become hot and finally catch fire in contact with air at ambient temperature without any application of energy, or

substances et préparations pouvant s'échauffer au point de s'enflammer à l'air à température ambiante sans apport d'énergie, ou


solid substances and preparations which may readily catch fire after brief contact with a source of ignition and which continue to burn or to be consumed after removal of the source of ignition, or

substances et préparations à l'état solide qui peuvent s'enflammer facilement par une brève action d'une source d'inflammation et qui continuent à brûler ou à se consumer après l'éloignement de la source d'inflammation, ou




D'autres ont cherché : self-heating may catch fire     self-heating may catch fire     


datacenter (1): www.wordscope.fr (v4.0.br)

'self-heating may catch fire' ->

Date index: 2024-02-04
w