Tube current-exposure time product
X-ray tube exposure cycle time

Traduction de «tube current-exposure time product » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
tube current-exposure time product

produit courant-temps d'exposition


TRADUCTIONS EN CONTEXTE
The product subject to this review is tube or pipe fittings (other than cast fittings, flanges and threaded fittings), of iron or steel (not including stainless steel), with a greatest external diameter not exceeding 609,6 mm, of a kind used for butt-welding or other purposes, currently falling within CN codes ex 7307 93 11, ex 7307 93 19 and ex 7307 99 80 (TARIC codes 7307931191, 7307931193, 7307931194, 7307931195, 7307931199, 7307931991, 7307931993, 7307931994, 7307931995, 7307931999, 7307998092, 7307998093, 7307998094, 7307998095 and 7307998098) (“the ...[+++]

«Les produits concernés sont des accessoires de tuyauterie (autres que les accessoires moulés, les brides et les accessoires filetés), en fer ou en acier (à l’exclusion de l’acier inoxydable), dont le plus grand diamètre extérieur ne dépasse pas 609,6 millimètres, du type utilisé, entre autres, pour les soudures bout à bout, et normalement déclarés sous les codes NC ex 7307 93 11, ex 7307 93 19 et ex 7307 99 80 (codes TARIC 7307931191, 7307931193, 7307931194, 7307931195, 7307931199, 7307931991, 7307931993, 7307931994, 7307931995, 7307 ...[+++]


The product subject to this review is tube or pipe fittings (other than cast fittings, flanges and threaded fittings), of iron or steel (not including stainless steel), with a greatest external diameter not exceeding 609,6 mm, of a kind used for butt-welding or other purposes, currently falling within CN codes ex 7307 93 11, ex 7307 93 19 and ex 7307 99 80 (TARIC codes 7307931191, 7307931193, 7307931194, 7307931195, 7307931199, 7307931991, 7307931993, 7307931994, 7307931995, 7307931999, 7307998092, 7307998093, 7307998094, 7307998095 and 7307998098) (“the ...[+++]

«Les produits concernés sont des accessoires de tuyauterie (autres que les accessoires moulés, les brides et les accessoires filetés), en fer ou en acier (à l’exclusion de l’acier inoxydable), dont le plus grand diamètre extérieur ne dépasse pas 609,6 millimètres, du type utilisé, entre autres, pour les soudures bout à bout, et normalement déclarés sous les codes NC ex 7307 93 11, ex 7307 93 19 et ex 7307 99 80 (codes TARIC 7307931191, 7307931193, 7307931194, 7307931195, 7307931199, 7307931991, 7307931993, 7307931994, 7307931995, 7307 ...[+++]


(2) For any combination of X-ray tube voltage, X-ray tube current and irradiation time, or for any selected exposure to the X-ray image receptor, when the line voltage for each measurement is accurate to within 1% of the mean line voltage value of all the measurements, and when all variable controls for the loading factors are adjusted to alternate settings and reset to the test setting before each measurement,

(2) Pour toute combinaison de la tension radiogène, du courant dans le tube radiogène et de la durée d’irradiation, ou pour toute exposition sélectionnée au récepteur d’image radiologique, lorsque la tension de secteur pour chaque mesure correspond à la valeur moyenne de la tension de toutes les mesures à 1 % près, et que toutes les commandes variables pour les paramètres de charge sont réglées à d’autres valeurs et ramenées à la valeur d’essai avant chaque mesure :


(e) at any fixed kilovoltage, the average ratios of milliroentgen exposure to milliampere-seconds obtained at any two consecutive tube current settings do not differ by more than 0.10 times their sum, namely,

e) à n’importe quel kilovoltage fixé, les rapports moyens d’exposition en milliroentgens et de milliampères-secondes, obtenus pour deux réglages consécutifs quelconques du courant du tube, ne peuvent dépasser 0,10 fois leur somme, c’est-à-dire,


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(B) the product of the X-ray tube voltage, X-ray tube current and irradiation time exceeds 60 kVAs per irradiation; and

(B) soit le produit de la tension radiogène, du courant dans le tube radiogène et du temps d’irradiation dépasse 60 kVAs par irradiation;


28 (1) Radioscopic equipment that has a feature described in column 1 of an item of the table to this subsection, other than when radioscopic images are being recorded, must not operate at any combination of X-ray tube voltage and X-ray tube current that results in an air kerma rate that exceeds that set out in column 2 of that item or an exposure rate that exceeds that set out in column 3 of that item:

28 (1) Tout appareil de radioscopie qui possède l’une des particularités indiquées à la colonne 1 du tableau du présent paragraphe ne doit pas pouvoir, sauf pendant l’enregistrement des images radioscopiques, fonctionner à une combinaison de tension radiogène et de courant dans le tube radiogène qui produit un débit de kerma dans l’air supérieur à celui figurant à la colonne 2 ou un débit d’exposition supérieur à celui prévu à la colonne 3.


(c) for any combination of kilovoltage, current and time, the coefficient of variation of any 10 consecutive radiation exposures, taken at the same distance within a time period of 1 hour, is no greater than 0.05;

c) pour toute combinaison de kilovoltage, courant et temps, le coefficient de variation de l’une des 10 expositions au rayonnement consécutives prises à la même distance, en une période de 1 heure, ne peut dépasser 0,05;


That Directive did not address the long-term effects, including the possible carcinogenic effects, of exposure to time-varying electric, magnetic and electromagnetic fields, for which there is currently no conclusive scientific evidence establishing a causal relationship.

Ladite directive ne traitait pas des effets à long terme, y compris des effets cancérigènes potentiels, pouvant découler d’une exposition à des champs électriques, magnétiques et électromagnétiques variant dans le temps, à propos desquels il n’existe actuellement pas d’éléments scientifiques probants qui permettent d’établir un lien de causalité.


Exposure of the body to a current generating at the same time a generalised epileptic form on the EEG and the fibrillation or the stopping of the heart.

Exposition du corps à un courant générant une forme épileptique généralisée sur l’électro-encéphalogramme et la fibrillation ou l’arrêt du cœur.


exposure limit values are provided for current density for time-varying fields up to 1 Hz, to prevent effects on the cardiovascular and central nervous system,

des valeurs limites d'exposition sont prévues pour la densité de courant pour les champs variables dans le temps jusqu'à 1 Hz, afin de prévenir des effets sur le système cardio-vasculaire et le système nerveux central.